Festool SYS-PST 1500 Li HP Notice D'utilisation page 24

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
English
1 > LED < 8 flash red
No fault indicator and consumer cannot be operated
Ensure that transport mode is deactivated: Set the transport switch [1-13]
to "I".
Ensure that the on/off switch [1-7] is switched on (see section 7.3) and the
LED indicator [1-9] lights up green.
If LED 1 flashes green, SYS‑PST 1500 Li HP is almost completely discharged
Charge SYS‑PST 1500 Li HP (see section 7.2).
Try to operate SYS‑PST 1500 Li HP again.
If no consumer can be operated, contact the manufacturer or service work­
shop (see section 10).
SYS‑PST 1500 Li HP does not charge
Ensure that transport mode is deactivated: Set the transport switch [1-13]
to "I".
24
If LEDs continue to flash yellow, switch
off again (see section 7.3) and leave to cool
down further.
In charging mode:
Wait until SYS‑PST 1500 Li HP has
cooled down. If necessary, open the
Systainer lid with T-Loc [1-5] and/or place
SYS‑PST 1500 Li HP in a cooler location.
The charging process automatically re­
starts after cooling.
System error
Switch off (see section 7.3).
Unplug the consumer.
Remove the charging cable [1-11] and
store it.
Restart SYS‑PST 1500 Li HP:
Switch on (see section 7.3).
If the LEDs light up in starting sequence,
the system error has been solved.
If the LEDs continue to flash red:
Switch off (see section 7.3).
Activate transport mode: Set the trans­
port switch [1-13] to "0".
Contact the manufacturer or service
workshop (see section 10).