8 . OPERATING TROUBLE

TROUBLES
8.1 THE PUMP WON'T START-UP
a) The pump is jammed :
OR STOPS UNEXPECTEDLY
b) The strips' screws have come loose :
c) The fuses are faulty :
d) The motor is damaged :
e) The circuit breaker-guard has been tripped :
f) The circuit-breaker-guard has been
g) The circuit-breaker-guard has been
h) The thermistor's trigger has started up. The
8.2 THE PUMPS IS OPERATING
a) The operating direction is incorrect :
AT A REDUCED FLOW RATE
b) The flow side valve is closed :
c) The rotation speed is too slow :
d) There is air in the suction piping :
8.3 THE PUMP MAKES A LOT OF
a) The suction pressure is not high enough :
NOISE AS IT RUNS
b) The motor's bearings are damaged :
c) The impeller is worn :

9. REPLACEMENT PARTS

Deliverable replacement parts (See FIG. 6)
A
Pump assembly.
A1
Impeller (with O-ring, nut and washer).
A2
Mechanical seal (with nut, washer, O-ring and spacing fork).
A3
Housing.
A4
Coupling device assembly.
A5
Shaft with spacing ring.
A6
Housing screw.
A7
Motor screw (with nuts and washers).
A8
Motor.
A9
Bleed screw.
B
Pump casing assembly (with O-ring).
C
Pump mounting for a motor power of ≤ 4 kW
(only for PBS pumps).
CAUSES
incorrectly set :
affected by too high an ambient
temperature :
CTP sensor has been triggered :
a) Turn off the motor and remove the cause of the problem. If the motor is still jammed, reattach
the motor and the pump or replace them.
b) Retighten all the terminals' screws.
c) Check all the fuses. Replace them if necessary.
d) Consult us.
e) Set the flow valve to the minimum flow rate.
f) Set the circuit breaker-guard to the correction nominal current written on the identification
plate.
g) Move the circuit breaker-guard or protect it with thermal insulation.
h) Check that the motor and the fan cover do not contain impurities, clean them if necessary,
check the ambient temperature, and, if required, bring it back up to 40°C through forced
ventilation. Check the motor coupling.
a) Check the rotation direction and change it if necessary.
b) Slowly open the valve.
c) Check the motor's start-up setting (Y instead of Δ).
d) Remove the air inlets at the flanges and drain.
a) Increase the suction pressure, comply with the minimum suction pressure at the suction flange,
check the outlet side valves and filters, cleaning them if necessary.
b) Have the pumps checked, and repaired if necessary, by the after sales service department.
c) Check, and, if necessary, clean the plane surfaces and the centerings between the housing
and the motor, and between the housing and the pump volutes.
Check the coupling device and shaft's contact surfaces, cleaning and lightly oiling them if
necessary.
When ordering replacement parts you must provide all the
information stated on the pumps' and the motor's identification
plates.
The pump can only be guaranteed to operate perfectly if factory-
approved parts are used.