A program window will now appear in which you should first set the "correct" COM port for the USB interface
(order no. 7168.6) in the selection window.
If you are not sure which port to use, check the COM port in the "Select Port" window in the "Menu" of the "Firmware_Up-
grade_grStudio" and note down the COM port number for the "Silicon Labs CP210x USB to UART Bridge" entry – in
this case "COM03". (If you select the wrong port, you will be alerted to this when you read out the receiver data). Click
on "File" to load the corresponding firmware file named "MicroStabi7X_V_XX.bin" from the hard disc ("XX" stands for
the version number).
When the file has loaded, click on start...
... connect the receiver and switch it on.
The progress bar shows that the transfer is running normally. The receiver LED lights up red and green during this
process and flashes red and green alternately once the transfer is complete.
Please refer to the detailed update instructions for the item in question in the Download area at http://www.graupner.de.