SHE control panel TRZ Plus 2A and TRZ Plus Comfort;
Compact control panel 2A and Compact control panel 2A/M
Technical datas
Automatic alarm unit output
Voltage:
Power:
Terminal:
Cable monitoring function:
max. Pieces:
Emergency power:
Buzzer/Signal lamp output or 27V output voltage source
Voltage:
Power:
Terminal:
Cable monitoring function:
max. Pieces:
Emergency power supply:
Fuse:
Mechanical properties
Dimensions:
Weight:
Circuit connections and operation
Connections:
Terminal connections:
Suitable for SHE:
Suitable for ventilation:
Ventilation function in the event of
mains failure:
Safety functions in the event of
mains failure:
Maintenance
Battery replacement:
Maintenance counter:
Maintenance counter active:
Functions after countdown of
maintenance counter:
Adjustable functions
Parameterisation:
Parameterisation by means of:
Options:
Installation and ambient conditions
Rated temperature:
Ambient temperature range:
Installation condition:
Function retention:
Suitable for external mounting:
IP protection system:
76
24 V nominal
max. 150 mA, 100 % ED
max. 1 mm², spring terminal
End resisted 10k or active end module
10
yes
27 V nominal
max. 100 mA, 100 % ED
max. 1 mm², spring terminal
no
1
no
no
see pages 63 - 64
TRZ Plus 2A: approx. 8 kg with battery, approx. 3 kg without battery
TRZ Plus Comfort: approx. 8 kg with battery, approx. 3 kg without battery
Compact Control panel 2A, 2A/M: approx. 15 kg with battery,
approx. 10 kg without battery
see technical documentation
see technical documentation
yes
yes
no, ventilation blocked
yes, automatic closure of the windows, ventilation blocked, while SHE continues to
be active: further functions via DIP-Switches
every 4 years and in the event of battery malfunction
yes, adjustable via PC Service Port Software
when power is supplied to the system, battery-backed
LED display
flashes, deactivation/activation of the via service port software
OK
yes
DIP-Switches, related software
maintenance counter, actuation limit, automatic ventilation,
Further functions dependent on the software and firmware versions.
20 °C
-5 °C to +40 °C
dry
Drives: 72 hours
Magnetic clamps: 1¼ hours
no
TRZ Plus: IP 30 in accordance with DIN EN 60 529
Compact control panal 2A: IP 44 in accordance with DIN EN 60 529
Compact control panal 2A/M: IP 20 in accordance with DIN EN 60 529,
IP30 when mounted
13/24999513