Compression Load Cell PR 6201
5.2
Installation of the upper load disc for max. capacity of 500 kg
50 t
Sartorius Intec
Note:
The figures below shows a schematic of load cell and upper load disc.
Small load cell radius (15 mm)
E
= 500 kg
10 t
max
Note:
Load discs made of stainless steel are marked with a double groove.
Further installation instructions can be found in the manuals of the respective
mounting kits.
Large load cell radius (35 mm)
E
= 20
50 t
max
5 Installation
EN-32