Donning The Facepiece; Facepiece Fit Check - MSA AirHawk II Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Check for bypass
operation. Grasp the
red knob and turn it
counter-clockwise.
Listen for airflow, then
turn it OFF. Close
cylinder valve fully.
8. Check for air leaks. Open cylinder valve fully to
pressurize system, then close the cylinder valve and
watch the harness pressure gauge.
9. If the needle drops more than 100 psi in 10 seconds,
there is a leak. Do not use the apparatus until the leak
is found and corrected.
10. Crack the bypass valve slowly to bleed off pressure
until gauge needle drops below:
550 psig - approximately (low-pressure system) or,
1125 psig – approximately (high-pressure system)
The alarm will sound. The alarm must continue to
sound until pressure is less than 200 psig. Close the
bypass fully.
If the alarm fails to sound, do not use the apparatus.
The air mask must be checked and corrected for
proper operation by an MSA trained or certified
repairperson before using. Failure to follow this
warning may result serious personal injury or death.
Note: Before donning, check that the regulator sealing
ring is seated properly in its groove, and that it is not torn,
gouged, or nicked.

DONNING THE FACEPIECE

Do not wear eye glasses under the facepiece. The
temples or sidebars on eye glasses will prevent an
airtight seal. if you must wear glasses, install the
spectacle kit. Failure to follow this warning can cause
inhalation of contaminated air, resulting in serious
respiratory injury or death.
When using the Advantage 4000 Facepiece, ensure the
inhalation valve disc is laying flat against the adapter
orifice.
1. Extend the facepiece straps fully. Place neckstrap
around your neck and don the facepiece by inserting
your chin first.
DONNING
2. Pull the head harness
completely over your
head and tighten the
lower (neck) straps.
3. Tighten the lower
(neck) harness straps
first, by pulling them
straight back, not out.
Tighten the temple
straps the same way.
Tuck in the ends of the
straps so that they lay
flat across the head.
4. Push headband pad towards neck, retighten the
straps (if necessary) for best visibility and fit. Tuck in
the ends of the straps so they lie flat across the head.

FACEPIECE FIT CHECK

Check the inhalation valve, inhale. If you do not
receive sufficient flow of air, do not use facepiece. The
facepiece must be repaired or replaced.
1. To check for facepiece
fit, hold the palm of
your hand over the inlet
connection and inhale.
Hold your breath at
least 10 seconds. The
facepiece should
collapse and stay
collapsed against your
face. If it does not,
readjust the facepiece
and test again. If this
does not correct the
leak, do not use the
facepiece.
7
Ultra Elite Facepiece
Advantage 4000 Facepiece
Ultra Elite Facepiece
TAL 1211 (L) Rev. 4 - 10088650