7.12 MAINTENANCE OF THE VIBRATING UNIT

Check the oil level after every 50 hours working with the compactor. Place the equipment on a flat,
horizontal surface. Unscrew the oil plug and washer. If the oil level is below the thread, top up with
oil and screw the oil plug back into place.
Change the oil after every 300 hours of operation.
en
!
7.12.1.
7.12.2.
7.12.3.
7.12.4.
7.12.5.
24
TEN2540-TEN2550-TEN3040-TEN3050
ATTENTION: The machine should be stopped or out of service.
Only empty out the oil when the machine is warm.
Danger of burns caused by hot oil!
Use current standard procedures for managing the residual oil.
Tilt the machine slightly to the opposite side from the one on which the oil is going to be
emptied out.
Remove the drainage plug for the vibrating oil (1).
Now tilt the machine to the other side and wait until all the oil has drained out.
Tilt the machine back the other way and refill with 1 L. of Shell MORLINA 100 oil.
Replace the plug.