B Measuring tolerances
Indication of the measuring tolerances Cx in ± (% of the reading + number of
digits = digit error)
Type
Operation
Capacity
with 120 Hz
test frequency
Capacity
with 1 kHz
test frequency
pF = pico-Farad = 10 exp. -12; nF = nano-Farad = 10 exp. -9; mF = micro-
Farad = 10 exp.-6
=========================================================
Inductivity
with 120 Hz
test frequency
Inductivity
with 1 kHz
test frequency
42
Measuring
Range
20 nF
200 nF
2 µF
20 µF
200 µF
2000 µF
10 mF
2000 pF
20 nF
200 nF
2000 nF
20 µF
200 µF
2000 µF
20 mH
200 mH
2000 mH
20 H (< 0.5H)
200 H (> 0.5H) ±(0.7%+5dgts) 10 mH
2000 H
10000 H
2000 µH
20 mH
200 mH
Precision
±(1.0%+5dgts) 1 pF
±(0.7%+5dgts) 10 pF
±(0.7%+3dgts) 100 pF
±(0.7%+3dgts) 1 nF
±(0.7%+3dgts) 10 nF
±(1.0%+5dgts) 0.1 µF
±(5.0%+5dgts) 1 µF
±(1.0%+5dgts) 0.1 pF
±(0.7%+5dgts) 1 pF
±(0.7%+5dgts) 10 pF
±(0.7%+3dgts) 100 pF
±(0.7%+3dgts) 1 nF
±(1.0%+3dgts) 10 nF
±(5,0%+5dgts) 1 µF
±(2.0%+5dgts) 1 µH
±(1.0%+5dgts) 10 µH
±(0.7%+5dgts) 100 µH
±(0.7%+5dgts) 1 mH
±(1.0%+5dgts) 100 mH
not specified
±(2.0%+5dgts) 0.1 µH
±(1,2%+5dgts) 1 µH
±(0.7%+5dgts) 10 µH
Dissolution
Calibration of
(SET mode)
open
open
---
---
---
short-circuit
(short)
short-circuit
open
open
---
---
---
short-circuit
short-circuit
short-circuit
short-circuit
---
---
---
open
1 H
---
short
short
---