Miller Syncrowave 250 DX Manuel De L'utilisateur page 28

Masquer les pouces Voir aussi pour Syncrowave 250 DX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

B. For 350 LX Models
NOTE
NOTE
50/60 Hertz Models
Input Voltage
Input Amperes At Rated Output*
Max Recommended Standard Fuse Or Circuit Breaker
Rating In Amperes
Normal Operating (Fast) Fuse
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG
* Input amperes at rated output is the amperage draw for that particular input voltage if the machine is run at its rated welding
output (see Section 3-3 for rated welding output).
Reference: 2005 National Electrical Code (NEC)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (fast) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
50/60 Hertz Models
Input Voltage
Input Amperes At Rated Output*
Max Recommended Standard Fuse Or Circuit Breaker
Rating In Amperes
Normal Operating (Fast) Fuse
Min Input Conductor Size In AWG
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG
* Input amperes at rated output is the amperage draw for that particular input voltage if the machine is run at its rated welding
output (see Section 3-3 for rated welding output).
Reference: 2005 National Electrical Code (NEC)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (fast) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
OM-363 Page 22
All values in both tables were calculated at 60% duty cycle.
Actual input voltage cannot exceed ± 10% of indicated required input voltage
shown in both tables. If actual input voltage is outside of this range, damage to unit
may occur.
200
125
1
Circuit Breaker
2
150
Time-Delay Fuse
3
175
4
3
151
(46)
4
6
200
92
1
Circuit Breaker
2
Time-Delay Fuse
110
3
125
4
4
145
(44)
4
6
Without Power Factor Correction
220
230
400
440
103
110
57
125
125
70
175
175
90
3
4
8
182
171
246
298
(56)
(52)
(75)
(91)
6
6
8
With Power Factor Correction
220
230
400
440
77
78
40
100
90
50
125
125
70
6
6
8
119
130
263
318
(36)
(40)
(80)
(97)
6
6
8
460
520
575
52
55
43
42
70
60
60
50
90
80
70
70
8
8
8
326
416
509
(99)
(127)
(155)
8
8
8
460
520
575
39
38
33
31
50
45
40
35
60
60
50
45
8
8
10
10
347
300
367
(106)
(91)
(112)
10
10
10
10
8
8