GB
IRL
S praying
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1.
Hang the device over your shoulder (Fig. 12).
To prevent dripping, hold the spray lance up when first spraying and activate the shut-
off valve until no more liquid mixed with air is emerging.
2.
Activate the shut-off valve [6] (Fig. 13).
►
Spraying may now begin.
3.
Make certain the optimum spraying pressure is set (→ Table 2) on the piston pressure
gauge [11] (Fig. 11).
S praying pres s ure
1.5 bar
2.0 bar
3.0 bar
Table 2. Relationship of: spraying rate and spraying pressure
4.
If the spraying pressure decreases more than 0.5 bar from the optimum level, pump
some more.
If liquid mixed with air emerges from the nozzle, the tank is empty.
After us age
Observe the instructions in the section entitled "Safety".
1.
Pull up the red button on the piston pressure gauge [11] until all excess pressure is
released from the tank (Fig. 5).
2.
Lock the piston rod with handle [12] (Fig. 6).
3.
Unscrew the pump [2] from the tank (Fig. 7).
Collect and dispose of the residual liquid according to all applicable laws,
requirements and regulations. Observe the instructions of the spray product
manufacturer!
4.
Empty and rinse the device with clear water.
5.
Wipe off the device with a moist cloth.
6.
For drying and storing the device, keep the tank [1] and pump [2] separate in a dry
place protected from sunlight and freezing temperatures (Fig. 14).
Clean the protective equipment and yourself every time after usage.
AUS
USA
S praying rate with flat jet nozzle (original equipment)
15
NZ
CDN
0.56 l/min
0.64 l/min
0.78 l/min
IND