Connection To A Computer Or Portable Serial Printer - Promax PROFI-70 Manuel D'utilisation

Analyseur des réseaux wifi
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USER'S MANUAL. PROFI-70
With the CHANNEL option by means of the key [F5], the equipment will analyse
the transmission channel selected trhough the navigation buttons [6]. If STATION
option is on using [F5] key, each time you press the navigation buttons [6], the
instrument will analyse the following transmitting station detected in this channel, in the
case that more than one exists.
The display shows the measurements obtained for the signal coming from the A
or B input selected (see section "4.2.2 CONFIG operation mode"). For example in the
previous figure, for the antenna input (A), it is indicated: channel power (PWR)
-32 dBm, SNR 28 dB, tuning frequency (FR) 2422 MHz corresponding to the channel
(CH) C03.
In this case a station has been detected (Stations:1) identified with SSID:
INTERMEC and MAC: 00:02:2D:3E:82:DB, which emits Beacon signals each 100 ms
and modulated signals (MOD) in OFDM, not encryted (Encrypt: No) through an ad-hoc
type network (MODE: Ad-hoc).
In the low part of the display appears the channel power value as an analogue
bar (PWR).

4.3 Connection to a Computer or Portable serial printer.

The PROFI-70 allows the connection to a PC or to a portable serial printer for
data transfer, by means of the connection cable model CC-208.
05/2008
Figure 13.- Measurement functions menu.
Page 23