Connecting components to the modular contacts (maximum cable cross-sectional area for RJ10. 0.9mm/ 0.2mm², AWG24)
Unit
Temp. sensor (10 kΩ)
External switch without LED
indication
External switch with LED indication
Door contact without alarm for door
status
Door contact with alarm for door
status
Position
Pin
Comment
1
2-3
Must be NTC type. May also be connected at Position 4.
2
3-4
Both constant and impulse deactivation work.
2
2-3-4
12VDC (maximum 40mA). Tylö external switch, item number: 9090
8045
3
3-4
Of type NO (Normally Open). Tylö door contact, Item No.: 9090 8035.
3
2-3-4
12VDC (max. 40mA)