Lighting; Positioning Of Thermistor; Connection To Extra Equipment; Home Automation - Tylo 2900 4160 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Home
1.
Strain relief connector for cable to motorized ball valve
2.
Strain relief connector for AUX and lighting
3.
Lighting fuse
4.
Strain relief connector for power supply cable
5.
Lead-through for the control panel, temperature sensor, etc. that will be connected by quick connectors to the circuit board.
Commercial
1.
Strain relief connector for cable to motorized ball valve
2.
Strain relief connector for power supply cable
3.
Lead-through for the control panel, temperature sensor, etc. that will be connected by quick connectors to the circuit board.
4.
Strain relief connector for AUX and lighting
5.
Lighting fuse
6.
Fan fuse

Lighting

Can be controlled from the control panel.
Refer to the connection label (Fig. 13) for the max. power specification.

Positioning of thermistor

The sensor is to be installed 150-170 cm above floor level inside the steam room. Important! The sensor must be located as far
from the steam jet as possible. It must not be in either direct or indirect contact with the steam jet.
The thermistor wire can be extended beyond the steam room by means of a low voltage wire (2-core). Refer to the section
"Modular connector description" for information on the pin configuration.
Option:
External switch - Can be positioned at any distance from the steam room. Connected by means of a low power cable and a RJ10
connector with pin connections as in the section "Modular connector description". Additional external switches must be connected
in parallel.
Door contact – Prevents unintended starting of the steam room while the door is open. Connected directly by means of a control
board and a RJ10 connector with low power wiring and pin connections as in the section "Modular connector description".

Connection to extra equipment

Possibility to connect extra equipment, such as fans, additional lighting, fragrance pump, etc. The number of functions it is possible
to connect is determined by the number of "AUX" inputs.
Product
Home
Commercial

Home automation

To start via a home automation system the input for external switches is used to trigger starting the steam generator. So as not to
risk inadvertent starting due to incorrect programming, it is recommended that a door contact is added to guarantee that the door is
closed. For other settings and programming, refer to the user's instructions for the control panel.
WARNING! SEVERAL POWER SUPPLY CIRCUITS. BEFORE WORKING ON THE EQUIPMENT, CHECK THAT IT IS
COMPLETELY WITHOUT VOLTAGE!

Multisteam

Steam Home and Steam Commercial 9/12/15kW offer the possibility of expanding and connecting together up to three facilities
served by the same control panel. This creates the possibility of unbroken steam production in all circumstances.
When more than one generator is connected together, one of them is set up to be the "Primary" (factory setting) and is the one
which controls the other generators. The other units are then set up to be "Secondary" in accordance with the DIP schematic
diagram at Fig. 17
Fig. 17
No. of AUX
1
3
28