Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical
shock.
• If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the
generator has been exceeded.
• Make sure that the electrical, rating of the tool or appliance does not exceed that of the generator. Never exceed
the maximum power rating of the generator. Power levels between rated and maximum may be used for no more
than 30 minutes.
NOTICE
Substantial overloading will switch off the circuit breaker.
Exceeding the time limit for maximum power operation or slightly overloading the generator may not
switch the circuit breaker OFF, but will shorten the service life of the generator.
Limit operation requiring maximum power to 30 minutes.
For continuous operation, do not exceed the rated power.
In any case, the total power requirements (VA) of all appliances connected must be considered. Appliance and
power tool manufacturers usually list rating information near the model number or serial number.
4) AC Operation
① Start the engine
② Switch the AC circuit breaker ON.
③ Plug in the appliance.
Most motorized appliances require more than their rated wattage for startup.
Do not exceed the current limit specified for any one receptacle. If an overloaded circuit causes the AC circuit
breaker to switch OFF, reduce the electrical load on the circuit, wait a few minutes and then reset the circuit
breaker.
5) DC OPERATION
DC Terminals
The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The terminals are colored
red to identify the positive (+) terminal and black to identify the negative (-) terminal. The battery must be
connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and
battery negative to the generator black terminal).
With DC Circuit Protector
DC Circuit Protector (or DC Fuse)
The DC circuit protector(or DC Fuse) automatically shuts off the DC battery charging circuit when the DC circuit is
overloaded, when there is a problem with the battery, or the connections between the battery and the generator
are improper.
With DC Fuse