With Electric Starter
Without Electric Starter
Return the key to the ON position once the engine has started. Do not use the starter for more than 5 seconds at a
time. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again.
2) Recoil Starter
To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly.
NOTICE
Do not allow the starter to snap back against the engine. Return it gently to prevent damage to the starter.
3) Fuel Valve
The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is
allowed to flow from the fuel tank to the carburetor. Be sure to return the lever to OFF after stopping the engine.
4) Choke
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by
operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the
mixture.
5) Circuit Breaker
The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator
at the receptacle. If the circuit breaker is switched OFF automatically, check that the appliance is working properly
and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again. The circuit
breaker may be used to switch the generator power ON or OFF.