Guidance And Manufacturer's Declaration -Electromagnetic Emissions - Pari Vios LC Sprint Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Guidance and manufacturer's declaration –electromagnetic emissions
The Vios
is intended for use in the electromagnetic environment specified below. The customer or the user of the
TM
Vios
should assure that it is used in such an environment.
TM
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations /
flicker emissions
IEC 61000-3-3
Guidance and manufacturer's declaration –electromagnetic immunity
The Vios
is intended for use in the electromagnetic environment specified below. The customer or the user of the Vios
TM
assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF
3 V/m
IEC 61000-4-3
80 MHz to 2,5 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the
measured field strength in the location in which the Vios
Vios
should be observed to verify normal operation. If abnormal performance is observed, additional measures may be
TM
necessary, such as re-orienting or relocating the Vios
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V
Compliance
Electromagnetic environment – guidance
The Vios
Therefore, its RF emissions are very low and are not
Group 1
likely to cause any interference in nearby electronic
equipment.
Class B
The Vios
including domestic establishments and those directly
connected to the public low-voltage power supply
Not applicable
network that supplies buildings used for domestic
purposes.
Not applicable
Compliance level
3 Vrms
150 kHz to 80 MHz
3 V/m
80 MHz to 2,5 GHz
is used exceeds the applicable RF compliance level above, the
TM
.
TM
Questions? 1.800.FAst.neB (327.8632) | PArI.com/VIos
uses RF energy only for its internal function.
TM
is suitable for use in all establishments,
TM
Electromagnetic environment
Portable and mobile RF communications equipment
should be used no closer to any part of the Vios
including cables, than the recommended separation
distance calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance
3,5
d =
P
V
1
3,5
d =
P
80 MHz to 800 MHz
E
1
7
d =
P
800 MHz to 2,5 GHz
E
1
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as deter-
mined by an electromagnetic site survey,
than the compliance level in each frequency range.
Interference may occur in the vicinity of equipment
marked with the following symbol:
] V/m.
1
should
TM
guidance
,
TM
a
should be less
b
EN-10