Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

InstructIons For use
For single patient use (one person) only
IncLuDes InstructIons For tHe PArI Lc
ImPortAnt: reAD InstructIons AnD sAFety PrecAutIons BeFore use
Read all waRNiNgs aNd iNstRuctioNs beFoRe use. use the pRoduct oNlY FoR its iNteNded use
as descRibed iN these iNstRuctioNs FoR use. iMpRopeR use caN Result iN seRious oR Fatal illNess/
iNjuRY, iMpRopeR tReatMeNt oR pRopeRtY daMage.
REMEMBER
Replace YouR Reusable NebulizeR cup eveRY siX MoNths
sPrInt neBuLIZer
®

Publicité

Table des Matières
loading

Sommaire des Matières pour Pari Vios LC Sprint

  • Page 1 InstructIons For use For single patient use (one person) only IncLuDes InstructIons For tHe PArI Lc sPrInt neBuLIZer ® ImPortAnt: reAD InstructIons AnD sAFety PrecAutIons BeFore use Read all waRNiNgs aNd iNstRuctioNs beFoRe use. use the pRoduct oNlY FoR its iNteNded use as descRibed iN these iNstRuctioNs FoR use.
  • Page 2 7. before use, check paRi Reusable Nebulizer for proper assembly. all parts should be seated firmly in place. use of an improperly assembled nebulizer could diminish or prevent ad equate delivery of medication and the effectiveness of the treatment.
  • Page 3 3. use only with accessories and cables authorized label correspond to the voltage and current available. by paRi for this device. use of this device with unauthorized accessories and cables may result in 2. Never operate this product if it has a damaged cord...
  • Page 4: Getting Started

    GettInG stArteD check your vios package to ensure you have the ™ following items. It is important to have a second PArI reusable nebulizer on hand at all times. air Filter air outlet power switch timestrip ® (timestrip location) ®...
  • Page 5 35 minutes at a time, Attach tubing to nebulizer cup: Firmly press the other ™ please contact paRi patient connection at 1.800.Fast.Neb end of the wing tip tubing to bottom of paRi ™ (327.8632).
  • Page 6 If activated at the time of first using the PARI reusable nebulizer then it will serve as a reminder that the PARI reusable WARNING nebulizer can be replaced.
  • Page 7: Maintenance & Repair

    ™ soak all parts of the paRi Reusable Nebulizer (except the filter will slowly turn grey, indicating the need for tubing and mask) in a solution of 1 part distilled white replacement.
  • Page 8: Explanation Of Symbols

    1 Measured by 7-stage cascade impactor, with membrane filter for 8th stage, equipped with a usp <601> throat, at 28 lpM continuous inspiratory flow. 2 Mass Median aerodynamic diameter 3 Respirable Mass delivered (0.5 – 5 µm) as a percentage of initial fill 4 total dose delivered by the nebulizer and captured by the impactor EN-7 Questions? 1.800.FAst.neB (327.8632) | PArI.com/VIos...
  • Page 9 LImIteD WArrAnty ® paRi reusable nebulizers include a 6 month limited warranty for home care use. if you have any problems and need to return your paRi reusable nebulizer, contact paRi patient connection at 1.800.Fast.Neb (327.8632). please be sure to clean and disinfect your paRi reusable nebulizer and place it in a plastic bag before returning.
  • Page 10: Guidance And Manufacturer's Declaration -Electromagnetic Immunity

    3 A / m 3 A / m of a typical location in a typical commercial or hospital IEC 61000-4-8 environment. NOTE U is the a.c. mains voltage prior to application of the test level. EN-9 Questions? 1.800.FAst.neB (327.8632) | PArI.com/VIos...
  • Page 11: Guidance And Manufacturer's Declaration -Electromagnetic Emissions

    If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Vios Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V ] V/m. Questions? 1.800.FAst.neB (327.8632) | PArI.com/VIos EN-10...
  • Page 12 Mode d’eMploi usage pour patient unique (une personne) Ces instruCtions s’appliquent aux nébuliseur lC sprint. iMportant : lire les instruCtions et les Mesures de séCurité soigneuseMent liRe les aveRtissements et le mode d’emploi soigneusement. le pRoduit doit êtRe employé eXclu- sivement auX fins auXquelles il se destine, telles que décRites dans le pRésent mode d’emploi.
  • Page 13: Indications D'emploi

    6. les patients âgés de moins de 4 ans ou ayant des besoins spéciaux doivent utiliser un masque au lieu de l’embouchure. 7. avant son utilisation, vérifier que le nébuliseur réutilisable paRi est correctement assemblé. les différentes pièces doivent être bien mises en place. un mauvais assemblage du nébuliseur peut gêner ou empêcher complètement la nébulisation du...
  • Page 14: Mesures De Sécurité - Vios

    électrocution, d’un incendie et de brûlures, ainsi 12. ne pas ouvrir ni démonter le compresseur paRi vios que les risques d’endommagement ou de dysfonctionnement confier l’entretien du produit à paRi.
  • Page 15: Démarrage

    (deux inclus) valve inspiratoire dessus du nébuliseur sortie du nébuliseur embouchure avecvalve expiratoire insert du nébuliseur bocal du nébuliseur entrée d’air tube avec raccords à ailette Wing-tip FR-3 Vous avez des questions? 1.800.Fast.neb (327.8632) | pari.com/Vios...
  • Page 16 35 minutes à la fois, veuillez communiquer rapporter à vos instructions de masque. avec la ligne patients de paRi au 1.800.fast.neb (327.8632). Fixez le tube au bocal du nébuliseur : appuyez fermement sur l’autre extrémité...
  • Page 17: Remplacer Le Bocal Du Nébuliseur Réutilisable Tous Les Six Mois

    L’autocollant Timestrip ne fait qu’enregistrer le passage du temps après son activation. Lorsqu’il est activé au moment de l’utilisation initiale du nébuliseur réutilisable PARI, il vous rappellera que le nébuliseur réutilisable PARI doit être remplacé. pouR RéduiRe le Risque d’infection : Le liquide contenu dans l’autocollant Timestrip...
  • Page 18: Compresseur

    également désinfecter les pièces du nébuliseur utilisez la pièce de monnaie pour visser le couvercle dans le réutilisable paRi (sauf le tube et le masque) en les faisant sens des aiguilles d’une montre bouillir dans un chaudron propre pendant dix minutes.
  • Page 19 : lorsque l'interrupteur est en position « arrêt » et que le CoMpresseur est éteint, le boîtier du CoMpresseur Contient toujours un potentiel éleCtrique. pour Couper l'aliMentation du CoMpresseur, il faut retirer le Cordon d'aliMentation de la sourCe d'aliMentation. FR-7 Vous avez des questions? 1.800.Fast.neb (327.8632) | pari.com/Vios...
  • Page 20 à...

Ce manuel est également adapté pour:

Go green viosLc sprint

Table des Matières