gefran SIEIDrive LIFT AGy-L Mode D'emploi page 231

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

LCD Display
I.502 Enc channels cfg
Encoder channels configuration
I.503 Enc spd mul fact
Multiplier factor of the encoder pulses, set in the I.501
I.504 Enc update time
Encoder pulses sampling time
I.505 Enc power supply
Encoder power supply level
I.506 Enc fault enable
Enable ENC alarm, Encoder cable break
I.600 Serial link cfg
Serial line configuration protocol & mode
I.601 Serial link bps
Serial line baudrate
I.602 Device address
Serial line address of the drive
I.603 Ser answer delay
Serial line answer delay time
I.604 Serial timeout
Serial line transmission timeout
I.605 En timeout alm
Setting time out alarm
I.700 Option 1 type
Expansion optional 1 card type
(Note: Selected board must be installed on drive)
I.701 Option 2 type
Expansion optional 2 card type
(Note: Selected board must be installed on drive)
I.750 SBI address
SBI Address
I.751 CAN baudrate
CAN Open baudraute
I.752 SBI Profibus mod
SBI Profibus Mode
I.753 SBI CAN mode
Selection of the Bus protocol
I.754 Bus flt holdoff
Delay time for Bus Fault Alarm
I.760 SBI to Drv W 0
Word 0 from SBI to drive
I.761 SBI to Drv W 1
Word 1 from SBI to drive
I.762 SBI to Drv W 2
Word 2 from SBI to drive
I.763 SBI to Drv W 3
Word 3 from SBI to drive
I.764 SBI to Drv W 4
Word 4 from SBI to drive
I.765 SBI to Drv W 5
Word 5 from SBI to drive
I.770 Drv to SBI W 0
Word 0 from drive to SBI
I.771 Drv to SBI W 1
Word 1 from drive to SBI
AGy -L
PARAMETER
DESCRIPTION
PICK LIST
LCD Selection
Description
[0] One Channel
A (K1) encoder channel
[1] Two Channels A and B (K1 and K2) encoder
channels
[0] 1ms
[1] 4ms
[2] 16ms
[3] 0.25s
[4] 1s
[5] 5s
[0] 5.2V
[1] 5.6V
[2] 8.3V
[3] 8.7V
[0] Disable
Encoder alarm disabled
[1] Enable
Encoder alarm enabled
Type(DataBit) Parity (StopBit)
FoxLink 7E1 (7) Even (1 )
[0] FoxLink 7E1
FoxLink 7O1 (7) Odd (1)
[1] FoxLink 701
FoxLink 7N2 (7) None (2)
[2] FoxLink 7N2
FoxLink 7O1 (8) None (1)
[3] FoxLink 8N1
[4] ModBus 8N1
Modbus 8N1 (8) None (1)
Jbus 8N1 (8) None (1)
[5] JBus 8N1
[0] 600 baud
600 baud rate
[1] 1200 baud
1200 baud rate
[2] 2400 baud
2400 baud rate
[3] 4800 baud
4800 baud rate
[4] 9600 baud
9600 baud rate
[5] 19200 baud
19200 baud rate
[6] 38400 baud
38400 baud rate
[0] Disable
Drive NOT in alarm and signal on
a digital output
[1] Enable
Drive IN alarm and signal on a
digital output
[0] Board Off
Reserved
[1] Board master
Reserved
[2] I/O Board
EXP-D6-A1R1-AGy
[3] Board free
Reseved
[4] SBI Board
SBI-PDP-AGy
[0] Board Off
Reserved
[1] Board master
Reserved
[2] I/O Board
EXP-D6-A1R1-AGy
[3] Board free
Reserved
[4] SBI Board
SBI-PDP-AGy
[0] 10 Kbit/s
[1] 20 Kbit/s
[2] 50 Kbit/s
[3] 125 Kbit/s
[4] 250 Kbit/s
[5] 500 Kbit/s
[6] 1000 Kbit/s
[0] Custom
Profidrive custom
[1] PPO1
Profidrive type 1
[2] PPO2
Profidrive type 2
[3] PPO3
Profidrive type 3
[4] PPO4
Profidrive type 4
[0] OFF
None
[1] CAN Open
CAN Open protocol
[2] DeviceNet
DeviceNet protocol
1
0
1
1
0.01
99.99
0
0
5
0
0
3
0
0
1
4
0
5
0.1
4
0
6
1
0
99
1
1
0
250
msec
1
0
0
25
sec
0.1
0
0
1
0
0
4
0
0
4
3
0
255
5
0
6
2
0
4
0
0
2
0.0
0.1
60.0
sec
0.1
0
0
1999
0
0
1999
0
0
1999
0
0
1999
0
0
1999
0
0
1999
1
0
1999
2
0
1999
IPA
152
153
154
181
197
155
156
157
158
159
160
161
162
163
164
165
166
179
167
168
169
170
171
172
173
174
231

Publicité

Table des Matières
loading

Table des Matières