LCD Display
I.001 Run Fwd src
Source of the Run Forward command of LCW
I.002 Run Rev src
Source of the Run Reverse command of LCW
I.003 Freq Sel 1 src
Source of the Frequency Selector 1 of LCW
I.004 Freq Sel 2 src
Source of the Frequency Selector 2 of LCW
I.005 Freq Sel 3 src
Source of the Frequency Selector 3 of LCW
I.006 Freq Sel 4 src
Source of the Frequency Selector 4 of LCW
I.007 Ramp Sel 1 src
Source of the Ramp Selector 1 of LCW
I.008 Ramp Sel 2 src
Source of the Ramp Selector 1 of LCW
I.009 Ext fault src
Source of the External Fault command of LCW
I.010 Faul reset src
Source of the Fault Reset command of LCW
I.011 Bak pwr act src
Source of the Backup Power Supply Active command of LCW
I.012 Forced stop src
Source of the Forced Stop command of LCW
I.100 Dig output 1 cfg
Digital output 1 configuration
228
PARAMETER
DESCRIPTION
PICK LIST
LCD Selection
Description
[6] DI 5
The command comes from
DigInp5
[7] DI 6
The command comes from
DigInp6
[8] DI 7
The command comes from
DigInp7
[9] DI 8
The command comes from
DigInp8
[10] DI Exp 1
The command comes from ExpDI
1
[11] DI Exp 2
The command comes from ExpDI
2
[12] DI Exp 3
The command comes from ExpDI
3
[13] DI Exp 4
The command comes from ExpDI
4
[14] AND 1
The command comes from the
output of the block AND1
[15] AND 2
The command comes from the
output of the block AND2
[16] AND 3
The command comes from the
output of the block AND3
[17] OR 1
The command comes from the
output of the block OR1
[18] OR 2
The command comes from the
output of the block OR2
[19] OR 3
The command comes from the
output of the block OR3
[20] NOT 1
The command comes from the
output of the block NOT1
[21] NOT 2
The command comes from the
output of the block NOT2
[22] NOT 3
The command comes from the
output of the block NOT3
[23] NOT 4
The command comes from the
output of the block NOT4
[24] FrqSel match The command is coming from the
output of the block Freq Sel
match
[25] ShortFloorFl
The command is the short floor
flag
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
As for I.000
[0] Drive Ready
[1] Alarm state
[2] Not in alarm
[3] Motor run
[4] Motor stop
[5] REV rotation
[6] Steady state
[7] Ramping
[8] UV running
3
0
25
4
0
25
5
0
25
6
0
25
7
0
25
0
0
25
25
0
25
0
0
25
8
0
25
9
0
25
0
0
25
0
0
25
51
0
55
AGy -L
IPA
101
102
103
104
105
106
107
108
109
110
111
185
112

Publicité

Table des Matières
loading

Table des Matières