Installation instructions
External Dim Box WSI
The electrical connection may only be made by a trained electrician.
• Unscrew the control module from the wall bracket. To do so, undo both screws
with the 3 mm Allen key (1).
• Unscrew the four screws (2) at the connection module and fold out the connec-
tion module.
• Feed the supply cable through cable gland (3) and connect to the terminals
labelled L↑, N↑ and PE.
• Feed the outgoing cables through cable glands (4) and connect to the termi-
nals labelled L1↓, N↓ and PE.
• If only one outgoing cable is used, screw the supplied blanking plug into the
second cable outlet (4).
• Tighten all cable glands with a 20 mm open ended spanner.
• Re-close the external dim box with the four screws (2) while ensuring the seal
is correctly seated.
• Fasten the wall bracket with suitable fastenings (not supplied - dependent on
the wall material) to the wall (observe the drilling template). Insert the control
module in the wall bracket and secure with the two M4x10 screws (1).
4
differentiation
3
inlet
2
PE
PE
L1
N
N
L1
2
PE
1
PE
PE
L1
N
N
L1
17
Drilling
connected
L1
N
L
44
08/2017
PE
PE
L1
N
N