Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
SPACING AT LEAST 3 MM AND WITH THE ADEQUATE CIRCUIT-BREAKING POWER. (see fig. 19).
The refrigerator must be installed by professionally qualified personnel, in accordance with the
instructions provided by the manufacturer and local regulations. Incorrect installation may cause
harm to persons, animals and property.
The manufacturer assumes no responsibility for such damage.
Make sure that the system power supply voltage corresponds to the values appearing on the rating
plate of the equipment. Consider also that the maximum allowable power voltage variation is +/-
6%.
The power cord must be spread out, safe from shocks and far from liquids, water and heat sources,
and in perfect condition. (IF THE CORD IS DAMAGED, HAVE IT REPLACED BY SUITABLY QUALIFIED
PERSONNEL).
Ensure that the available power voltage matches the values on the rating plate of the equipment.
Consider also that the maximum voltage fluctuation allowed is +/-6%.
Before connection, check that the power source impedance is equal to or lower than
0,383 Ohm.
POWER CORD: WHITE/ LIGHTING CORD: BLACK
IMPORTANT: THE EQUIPMENT MUST BE PROPERLY EARTHED. The manufacturer assumes
no responsibility for any damage resulting from non-observance of this safety principle.
If the cabinet must be installed far from electric power source, make certain that the
connection complies with the standards in force.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE ARISING FROM INCORRECT INSTALLATION.
6. TECHNICAL SPECIFICATIONS
The built-in electrical installation is composed of control devices lodged in the upper part of the
refrigerated cabinet. The technical details, which are also reported on the rating plate, inside the
display case (see fig. 7 on page 8) are shown in table III, page 8.
The sound pressure generated at 1m by the equipment is below 70 dB(A). This refrige-
rated cabinet generates no harmful vibrations.
WE HEREBY DECLARE THAT THE DISPLAY CASE AT ISSUE COMPLIES WITH D.L. (DECREE LAW)
DATED 25/JAN/1992 N° 108 AS EXECUTING EEC DIRECTIVE 89/109 ON MATERIALS AND OBJECTS
FIT FOR CONTACT WITH EDIBLES.
WE HEREBY DECLARE THAT THE SHOWCASE AT ISSUE IS ADEQUATE FOR THE PRESERVATION OF
FROZEN PRODUCTS IN COMPLIANCE WITH LAW No. 283 DATED 30/APRIL/42 AND SUBSEQUENT
AMENDMENTS, AND DECREE LAW OF 29/JAN/81 PUBLISHED IN THE OFFICIAL GAZETTE dated
26/MARCH/81 No. 85.
7. LOADING PRODUCTS
Once the technicians have completed cabinet installation, turn power on. The cabinet will then start
its cooling cycle. Allow about two hours before loading products, which must already be at their
preservation temperature. THE DISPLAY CASE IS FACTORY-REGULATED FOR THE ANTICIPATED
PERFORMANCE.
GRANBERING INTEGRAL
NC5xSyD
Epta Spa - Unità locale: Via degli Alpini 14 - 32020 Limana (BL)
ITALIA Tel. 0437/9681 Telefax 0437/967434
24/45
PAGE:
UM000329
N° DOC.