26. Changing the position of the control panel
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply to the motor and to the
signal relays. Wait at least 5 minutes before
starting any work on the motor. Make sure that the
power supply cannot be accidentally switched on.
You can turn the control panel 180 °. Follow the instructions
below.
1. Loosen the four screws, TX25, of the terminal box cover.
Fig. 80 Loosening the screws
2. Remove the terminal box cover.
Fig. 81 Removing the terminal box cover
3. Press and hold in the two locking tabs, A, while gently lifting
the plastic cover, B.
Fig. 82 Lifting the plastic cover
64
4. Turn the plastic cover 180 °.
Do not twist the cable more than 90 °.
Fig. 83 Turning the plastic cover
5. Position the plastic cover correctly on the four rubber pins, C.
Make sure that the locking tabs, A, are placed correctly.
Fig. 84 Re-positioning the plastic cover
6. Fit the terminal box cover, and make sure that it is also turned
180 ° so that the buttons on the control panel are aligned with
the buttons on the plastic cover.
7. Tighten the four screws (TX25) with 3.69 lbf-ft (5 Nm).
Fig. 85 Fitting the terminal box cover