Extraction Arm Use; Qualification Of The Operating Personnel; Positioning The Exhaust Hood - Kemper 79 002 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
6

Extraction Arm Use

6.1

Qualification of the operating personnel

6.2

Positioning the Exhaust Hood

Fig. 6-1: Welding fumes absorption
Art.- Nr.: 1502197
Extraction Arm Use
Any person who deals with the use, maintenance and repair of the
extraction arm must have read and understood these operating
instructions thoroughly.
For an independent use, the operator of the extraction arm can only
instruct persons who are familiar with this task.
Being familiar with this work includes that the persons have been
trained according to the task and understand the operating manual and
the operating instructions in question.
The extraction arm can only be used by trained personnel.
Only this way it can be ensured that all personnel work in a safety
conscious and risk-aware manner.
WARNING
Inhaling welding fumes can cause severe damage to health!
Perform welding work only when the arm is set correctly
for the extraction of welding fumes.
Through the elongated shape and the 360° rotation of the
exhaust hood, it remains continuously adjusted to the welding
seam (1). It is adjustable to any position with one hand. The
flange-type cover to the sides increases the extraction range. The
exhaust hood should be positioned at a distance of about 30 cm
above the weld. For adequate detection of welding fumes, a
suction flow rate of more than 700 m
information under Section Technical Data.
Due to the shape of the vacuum field (2), the exhaust hood must
not be tracked as often.
3
/h is required. Also note the
6-1