Assembly of the Extraction Arm onto a Wall or a
Hinged Cantilever (Extraction Arm Length 2.0m, 3.0 m, 4.0 m)
Fig. 5-2
Art.- Nr.: 1502197
Assembly
WARNING
Falls and falling components can cause serious injuries.
The extraction arm is mounted at a height of approximately
2,300 mm. By improper handling you and/or the components
may fall.
● Use appropriate ascending aids or working platforms.
● Do not stand or walk under suspended loads.
Extraction arm length [m]
2
3
4
● Check or ensure that the wall or column have sufficient load
bearing capacity before starting the assembly.
Note
On the upper mounting screws, tensile forces with up to
2,800 N (ca. 280 kg) act on each mounting screw.
● Align the wall console (1) with a spirit level.
● Attach the wall console (1) according to the adjacent drilling figure
onto a load-bearing surface. Use suitable screws (Ø10) and
dowels.
Torque at the wall console [Nm]
450
700
1,000