1. General Machine Description

The Green Pointer Pro is a patented grinder for wet
grinding of tungsten electrodes for TIG welding. It is
very easy and safe to use.
The diamond disc grinds the tungsten electrodes
correctly in the longitudinal direction of the electrode,
and the variable angle adjustment allows, not only to
grind in the right angle, but also to grind the tip flat,
if needed.
The grinding liquid in the closed grinding chamber
ensures that no harmful dust particles slips out into
the surroundings. The cooling effect of the grinding
liquid also means that there are no discoloration of
the tungsten electrode due to heat.
The harmful grinding dust is collected automatically in
the special dust collector and hence can be disposed
correctly.
The included electrode holder and electrode clamps,
in combination with stick-out adjustment, reduces the
waste of electrodes, and ensures a uniform grinding
result at each grinding.
The Green Pointer Pro can opperate in a room with
an ambient temperature of 0°C to + 40° and a relative
humidity of up to 50% at 40°C and 90% at 20°C. The
machine has been tested acc. Protection class IP21.

2. What is included?

Upon receipt and unpacking please check, that the
following items are included in the package:
• Green Pointer Pro machine with a diamond disc
• Dust Collector with grinding liquid
• Bottle with 250ml grinding liquid
• Tungsten electrode holder
• Electrode clamp ø1.6mm
• Electrode clamp ø2.4mm
• Electrode clamp ø3.2mm
• Worktable incl. bolts and nuts for mounting

3. Operational elements

6
5
1. Power Switch
2. Transport handle
3. Degree scale
4. Electrode holder
5. Stick-out adjustment
6. Tightening screw
7. Reset button
8. LED warning light

4. Initial Operation

Remove the protective foil on the enclosed worktable
and mount the worktable as shown in the drawing
in the back of this manual. Fasten the grinder on the
worktable and place it securely on a workbench or
table.
IMPORTANT: The Green Pointer Pro cannot run
without grinding liquid!
The Green Pointer Pro grinder does not contain
grinding liquid on delivery. Before starting the
machine the first time, mount the supplied dust
collector and fill extra grinding liquid from the bottle
through the tube until the correct liquid level has
been reached (please see mark on the inspection
cover frame).
Check that the switch is in the OFF position. ("O" on
the switch)
Connect the machine to the mains voltage specified
on the nameplate.
IMPORTANT: Only use single-phase power supply
outlet WITH an earth connection.