MINIMUM MANTEL OR SHELF CLEARANCES

3.9
minimum mantel or shelf clearances
WARNING
!
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
Risk of fire!
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
Maintain all specified air space clearances to combustibles.
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, HEARTH, MANTEL, FRONT,
Failure to comply with these instructions may cause a fire or cause the appliance to overheat.
Ensure all clearances (i.e. back, side, top, vent, hearth, mantel, front, etc.) are clearly maintained.
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25 at a minimum
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25-1 at a minimum distance
distance of 8" (203mm).
of 8" (203mm).
COMBUSTIBLE
MANTEL OR
TRIM MATERIAL
ETC.) ARE CLEARLY MAINTAINED.
MAX. MANTEL DEPTH
8" (203mm)
MIN.
WARNING
!
COMBUSTIBLE
NON-COMBUSTIBLE
12" (305mm)
2" (51mm)
2"
(51mm)
installation
BRICK
0" (0mm) IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND STONE
1" (25mm)
24 1/2"
(622mm)
W415-2207 / C / 08.23.18
W415-1332 / A / 11.21.14