4.9
MINIMUM MANTEL OR SHELF CLEARANCES
3.9
minimum mantel or shelf clearances
WARNING
!
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
•
Risk of fire!
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
•
Maintain all specified air space clearances to combustibles.
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, HEARTH, MANTEL, FRONT,
•
Failure to comply with these instructions may cause a fire or cause the appliance to overheat.
•
Ensure all clearances (i.e. back, side, top, vent, hearth, mantel, front, etc.) are clearly maintained.
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25 at a minimum
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25-1 at a minimum distance
distance of 8" (203mm).
of 8" (203mm).
COMBUSTIBLE
MANTEL OR
TRIM MATERIAL
ETC.) ARE CLEARLY MAINTAINED.
MAX. MANTEL DEPTH
8" (203mm)
MIN.
WARNING
!
COMBUSTIBLE
NON-COMBUSTIBLE
12" (305mm)
2" (51mm)
2"
(51mm)
installation
BRICK
0" (0mm) IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND STONE
1" (25mm)
24 1/2"
(622mm)
W415-2207 / C / 08.23.18
W415-1332 / A / 11.21.14
25
EN
EN
25