After taking pressure readings, be sure to turn screws
clockwise firmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
Pressure
Inlet
(minimum 4.5")
Outlet
8.4

flame characteristics

It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
Natural Gas
Natural Gas
(inches)
(millibars)
*7"
17.4mb
(minimum 11.2mb)
3.5"
8.7mb
Propane
(inches)
13"
(minimum 11")
10"
*Maximum inlet pressure not to exceed 13"
ADD IMAGE
HERE
FLAME
SENSOR
SPARK MODULE
adjustment
Propane
(millibars)
32.4mb
(minimum 27.4mb)
24.9mb
25.1
PILOT
BURNER
36.1
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO
1/2" (12.7mm) OF FLAME
SENSOR
W415-2207 / C / 08.23.18
EN
37