ATTENTION! The relay load must be observed for this! A pump
with too high a current consumption can damage the relay. An
additional contactor and motor protection must be installed. This
also applies for three-phase current pumps.
Relay 5
Relay 6
Relay 7
Relay 8
Relay load
AC3
AC1
Assignment of the digital inputs on the RasPI
Only use the 12 V from terminal X2:1-4 for digital inputs.
Maximum current load 200 mA.
I01
I02
I04
I05
I06
I07
I09
I10
I11
I12
X8 Fuses; 230 V power supply
X8:F1 (T 1.25 A)
X8:F2 (T 6.3 A)
BADU Genio external wiring
Relay connection designation (left-middle-right) looking at the
screw terminal from the front.
Low voltage
Inputs for attractions when switched by piezo/PN switch
additionally to the app.
Button1/Attraction1
Conductor1
Conductor2
09|2019
Backflushing
NO (normally open)
Rinsing
NO (normally open)
Emptying
NO (normally open)
Circulation
NO (normally open)
250 V/2 A
250 V/10 A
Chlorine canister empty message
pH canister empty message
Pressure switch
Level switch
Enable BADU Omni actuating drive
Switch for emptying
Button for attraction 1
Button for attraction 2
Button for attraction 3
Factory settings (5 s)
Fuse 5 V Raspberry Pi
Fuse terminal strip X8:L; power supply unit
24 V
X2:1 (12V)
I09
Installation