Installation
5.2.1

Terminal assignment plan

Operating voltage: 230 V, 50/60 Hz
Fixed wiring is necessary for permanent operation!
Assignment of the output relay RasPl
Motherboard:
Relay 1 (X7:1/2/4)
Relay 2 (X7:11/12/14)
Relay 3 (X7:21/22/24)
Relay 4 (X6:5)
Relay 5 (X6:4)
Relay 6 (X6:3)
Relay 7 (X6:2)
Relay 8 (X6:1)
Daughterboard:
Relay 1
Relay 2
Relay 3
Relay 4
If a normal AC pump is installed instead of a speed-controlled
pump, the pump must be connected to relay 4 (Stop) as a closer
(NO).
14 EN
Level
Attraction 1
Attraction 2
Attraction 3
Floor drain ball valve
Heating
Redox dosing pump
pH dosing pump
n1
NO (normally open)
n2
NO (normally open)
n3
NO (normally open)
Stop
NC (normally closed)
potential-free
potential-free
potential-free
09|2019