Operation
Rod valve for rinsing:
Connect the rod valve for rinsing to relay 6 of the daughterboard
and set the duration of the rinsing process in the switching times.
Use without rinsing valve:
It is recommended to set the rinsing time to "0". The pump then
switches directly to automatic operation after the backflushing
process and skips the rinsing process.
The rinsing process is not skipped if a rinsing time is set. The
pump runs in speed stage 3 for the set time.
Contact "L" must be switched when using a rod valve with 230 V
operating voltage. The bridged GND must be removed for this.
Details can be found in the wiring diagram.
7.10.5 Winter function
The winter function prevents the pool water from freezing in frosty
weather. During winter mode, the water circulates and no longer
passes through the filter. The winter function is only possible in
connection with a BADU Omni actuating drive. The "Circulate"
function is not assigned if a rod valve is used.
The "Winter operation" function can be selected under mode in
automatic backflushing. All functions are locked but are still
displayed when this has been selected. Pump pressure
monitoring remains active. The BADU Omni actuating drive
moves to the circulation position.
50 EN