Thermal fuse: The saw is equipped with a
thermal fuse to protect against overheating
(motor burn-out). The protection circuit turns
the motor off before reaching a critical motor
temperature. After cooling down for approx. 3
– 5 minutes the plunge saw is again ready to
use and fully operational. In idle speed the
cooling period of the plunge saw is
considerably reduced.
Current limitation: The current limitation
prevents too high current draw during extreme
overload. This can cause reduced motor
speed. After load relief the motor starts up
again immediately.
Constant speed: The preset motor speed is
electronically kept. This allows for continuous
cutting speed even under load.
Selector switch: Use the selector switch (20)
to set the respective operation mode.
Change Saw Blade
Plunge Cut
Marked Cut
Speed setting:
The speed regulator (4) allows setting the
motor speed infinitely variable between 2000
and 5000 min
. The cutting speed can be
-1
optimal adjusted for the respective materials.
Turn the speed regulator (4) towards 1 to
reduce the motor speed; turn the adjusting
wheel towards 6 to increase the speed.
26
7062938-T-Raxx-1400W-Ma-1801-23.indd 26
The respective motor speed depends on type
and thickness of the work piece. Observe
directions below for cutting materials with the
appropriate speed:
Speed range 1 – 3:
Gypsum and cement-bonded fiberboard,
plastics (soft), non-ferrous metals
Speed range 4 – 5:
Plastics (hard), fiber-reinforced plastics (GRP),
paper and fabrics, particle and hard boards,
acrylic glass (Perspex)
Speed range 5 – 6:
Solid wood (hard, soft), plywood, core boards,
veneered and coated boards, plastic-coated
boards, MDF boards
Notes: At higher speed settings you cut the
material faster, but this reduces the life cycle
of the saw blade.
Reduce the speed for clean cuts in heat-
sensitive and soft materials.
Do not use the speed regulation to use saw
blades for lower nominal speed. Only use saw
blades with a minimum speed of 5000 rpm.
SWITCH PLUNGE SAW ON/OFF
1. Press the switch lock (1) and then the ON/
OFF switch (2) to switch the plunge saw on.
2. Release the ON/OFF switch (2) to switch
the plunge saw off.
Notes: Pressing the switch lock (1) unlocks
the plunge cut mechanism at the same time,
so that the motor can be moved downwards.
The saw blade emerges from the protective
cover. When lifting the saw the motor slides
back into the initial position.
SET CUTTING DEPTH
The cutting depth can be set between 0 - 54
mm:
1. Loosen the cutting depth limit stop knob
05-03-18 10:16