Important installation instructions:

The roof construction must be checked on site to ensure it can absorb the
transferred forces!
The industrially prefabricated profiles must be machined according to the respective
manufacturer's specifications. Their installation guidelines are prerequisite and binding
for installation of the
The maximum allowable clip spacing with boards is 2.5 m!
The double standing seam profiles, made by hand or on small profiling machines, must
be used according to the technical rules for metalworking in the roof trade. The proper
use documented there is prerequisite and binding for installation of the
FALZ-PLUS
fall protection devices.
®
The
LUX-top
FALZ-PLUS
using the fixings supplied by the manufacturer and according to the installation
instructions! The installation must be checked appropriately!
The anchor point must be installed on a surface/substrate with sufficient load bearing
capacity in accordance with the manufacturer's specifications. Always ensure
compliance with the minimum component dimensions and distances from edges given
in the installation instructions!
The overall construction must be checked on site to ensure it can absorb the
transferred forces!
The installers must ensure that the surface is suitable for fixing the anchor device.
The anchor point may only be fixed on the fixing substrates named in Table 1 with
corresponding material thickness. The distance between standing seams can be
between 330 mm and 610 mm.
All connections of the anchor device must be properly and conscientiously installed
and checked according to the manufacturer's specifications. This must be confirmed by
the responsible fitter in the installation documentation form attached to these user
instructions.
The installation documentation form must be filled in full following installation and
handed over to the building owner/user or kept in a protected place with the parts of
the equipment that are not permanently installed.
We recommend that you also additionally document proper installation by taking
photos and with other important installation data. We recommend that you use our
documentation app for this, available at
Additional information to that given in the installation documents is provided in EN
795:2012 (Annex A).
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection – www.lux-top-absturzsicherungen.de
®
LUX-top
FALZ-PLUS
may only be installed by qualified installation personnel
www.quick-doku.eu
page 6
version 01/2016
fall protection devices.
®