1.2 Installation with embedded sleeve for screwing in the anchor sleeve.
1a
2a
Installation characteristics
Minimum concrete quality (strength class):
Minimum thickness of structural member:
Minimum distance from the edge:
Minimum depth of engagement in concreted in sleeve:
Maximum anchor sleeve protrusion above the concrete:
Always contact the manufacturer in case of different basic conditions!
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection – www.st-quadrat.lu
1.
Fix the plastic threaded plug onto the required
position by means of a screw on the formwork
linking.
2.
Screw the embedded sleeve completely onto
the threaded plug.
3.
Concrete
Note the installation characteristics!
4.
When removing the formwork, leave the
plastic threaded plug in the embedded sleeve
as protection against dirt. Do not remove it
until all construction work is finished.
5.
Screw the previously cleaned anchor sleeve
into the embedded sleeve using suitable liquid
thread
protrusion (e.g. in case of plastered ceilings)
can be made by turning the anchor sleeve in
or out. The anchor sleeve must not be set
back behind the finished structure, but
must at least end flush!
1b
2b
C20/25
120 mm
120 mm
55.0 mm
250 mm
Page 8 Version 05/2015
the
structural
locker.
Finer
adjustments
member.
to
the