The lanyard must always be set as short as possible, even when fall arrest systems are
used, in order to reduce any free-fall height in case of a fall to a minimum. It is essential
for safety that the position of the anchor device and the plan of work be chosen so that the
free fall and the fall height are limited to a minimum. Ideally, a fall over the edge
should be completely prevented by appropriate use of the PPE against falls from
a height.
Please note that failing to follow these user instructions, and if the documentation is
incomplete, all claims for compensation are excluded.
The manufacturer must be contacted in case of any uncertainty during installation or use
of the system!
A standard operating procedure with information on the location and use of the anchor
devices should be attached at the access to the safety system (e.g. roof hatch).
Installation instructions:
®
The
LUX-top
KLICK II
anchor sleeve and fixings supplied with it and according to the installation instructions!
The anchor point must be installed on a substrate with sufficient load bearing capacity in
accordance with the manufacturer's specifications. Always ensure compliance with the
minimum dimensions specified in the installation instructions!
The whole structure must be checked on site.
The installers must ensure that the surface/substrate is suitable for fixing the anchor
device.
All connections of the anchor device must be properly and conscientiously installed and
checked according to the manufacturer's specifications. This must be confirmed in the
inspection log card attached to these user instructions by the responsible fitter.
The Installation documentation must be fully completed following installation and handed
over to the building owner or kept in a protected place together with the parts of the
equipment not permanently installed!
We recommend that you also additionally document proper installation by taking photos
and
with
other
documentation app for this, which you can find at
Additional information to that given in the installation documents is provided in EN
795:2012 (Annex A).
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection – www.st-quadrat.lu
may only be installed by qualified installation personnel using the
important
installation
Page 4 Version 05/2015
data.
We
recommend
www.quick-doku.eu.
that
you
use
our