Télécharger Imprimer la page

SKF HMV Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
Figure 9. Dial indicator and hydraulic pump.
Dial indicators (ig. 9a)
Calibrated in millimetres
Calibrated in inches
Hydraulic pumps with digital pressure gauge (ig. 9b)
0 - 100 MPa (0 - 15 000 psi)
Maximum nut size
Pump reference
Step by step mounting procedure
Step 1
Ensure that the bearing size is compatible with the HMV(C) E nut size. For example, for
bearing 23936 CCK/W33 mounted direct on a shaft, use HMV(C) 36E. Otherwise the
pressure corresponding to the starting position must be adjusted.
Step 2
Determine whether one or two surfaces slide during mounting. See igures 10 - 13.
Step 3
Drive the bearing up to the starting position by applying the correct hydraulic pressure to
the HMV(C) E nut. See igure 14.
As an alternative, the SKF digital pressure gauge can be screwed directly into the hydraulic
SKF HMV / HMVC
Il Cuscinetto srl - www.ilcuscinetto.it - info@ilcuscinetto.it
TMCD 10R / TMCD 5P
TMCD 1/2R
HMV (C) 54E
HMV (C) 92E
729124 DU
TMJL 100DU
HMV (C) 200E
TMJL 50DU
9