Selecting Proper Pump Size; Pump Requirements - Paramount PCC2000 Manuel D'installation

Système de circulation et de nettoyeur de plancher automatique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Determine GPM and Ft./Hd. requirements from Specification Chart below.
2. Refer to manufacturer's pump curve of equipment you use.
3. Compare Part # and Model #. Do not rely on horsepower. Most manufacturers make both full-rated and up-rated pumps. This also relates to low
and high service factors.
4. Most pump curves will show Total Head in Feet on the left side vertically. Gallons per Minute are indicated horizontally across the page.
5. Draw an x where the two lines intersect. This will give you the pump required.
In-floor System Specification Chart
SINGLE PUMP
*65 GPM @ 70 TDh
Filter/ Cleaner Pump
* Any time the equipment is more than 50 ft. away from skimmer, special engineering is required. Submit a copy of the proposed plan indicating
the specific information to Paramount Pool & Spa Systems.
* GPM stated are the requirements of the in-floor system. Additional equipment such as chlorine generators, spa overflows, etc., require more
water flow. Adjust pump GPM requirements accordingly.
SINGLE PUMP
OTHER FLOW CONCERNS

Selecting Proper Pump Size

MIN. FILTER
4.9 Sand
48 Sq.Ft. D.E.
200 Sq.Ft. Cart.
No Multi-Port
Filter Valves
bypass On heater

PUMP REQUIREMENTS

DUAL PUMP
*50 GPM @ 60 TDh
Cleaner Pump
75 GPM @ 60 TDh
Filter Pump
DUAL PUMP
6
MIN. FILTER
3.1 Sand
36 Sq.Ft. D.E.
200 Sq.Ft. Cart.
Multi-Port Ok.
No bypass On heater Required
*
*
*Dual pump systems may
be multiport valves and do
not need heater bypass.