Fixed Directors

Plumbing For Floor Nozzles
2- 1/2" CAP
TOP OF
2- 1/2"
SHOTCRETE
SCH 40
CONCRETE
SOIL
PIPE SIZE
PER PLAN
REDUCE HERE
2-1/2 X 2 REDUCER 90 DEGREE ELBOW
Fixed Directors
Note location of fixed directors is always located halfway between two (2) rotating nozzles. Fixed Directors are located an equal distance from the
main drain a minimum of 4-5 feet and no more than 9 feet.
Follow system detail plan for actual location of fixed nozzles.
Off-Set Pattern
Direct Pattern
For Most
For Most
Deep-End Pools
Center-Depth
Pools
10