Plumbing Heaters, Solar Systems, Heat Pumps - Paramount PCC2000 Manuel D'installation

Système de circulation et de nettoyeur de plancher automatique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Plumbing Heaters, Solar Systems, Heat Pumps

HEATERS
When installing a heater on the pool, a
1" bY-PASS TO PARTIALLY DIRECT
WATER AROUND ThE hEATER IS
NECESSARY. This allows part of the
water through the heater for heating
but limits the head loss created when
all the water is directed through the
heater. ThE IN-FLOOR SYSTEM
WILL NOT FUNCTION PROPERLY
WIThOUT ThIS bY-PASS.
SOLAR SYSTEMS
Paramount recommends
solar systems be operated
independently with a booster
pump, separate suction, and
returns, or as shown below with
a secondary booster pump, and
the in-floor system valve installed
after the solar and heater pack.
HEAT PUMP
heat pumps must have a
minimum by-pass of 1 ½" with
a gate valve for adjustment. The
gate valve must be set with a
temperature probe to factory
specs for heat rise.
FROM
FROM
SKIMMER
MAIN
DRAIN
BALANCING
VALVE
BALANCING
VALVE
PUMP
FILTER
BACKWASHING
VALVE
CHECK
VALVE
1" BYPASS
HEATER
LINE
WATER
VALVE
COLLECTOR
PANELS
SOLAR SENSOR
FILTER
16
CHECK
VALVE
IMPORTANT
MANUAL
1" BYPASS
LINE
VACUUM BREAKER
IN-LINE
BOOSTER
PUMP
CHECK
VALVE
RETURNS
CLEANING
SYSTEM
POOL PUMP
POOL SYSTEM
HEATER
1 1/2 INCH
GATE VALVE

Publicité

Chapitres

Table des Matières
loading

Table des Matières