GROUP S.P.A.
The values S1-6, S1-7 and S1-8 of dip-switch S1 on bracket Art. 5914KC, define the mode in which the Maestro KIT System will operate, as
shown in the following table.
S1-6
S1-7
OFF
OFF
(0)
(0)
ON
OFF
(1)
(0)
OFF
ON
(0)
(1)
ON
ON
(1)
(1)
OFF
OFF
(0)
(0)
ON
OFF
(1)
(0)
OFF
ON
(0)
(1)
(1)
The two-residence intercom call (between door-entry phones and/or video door-entry phones) is possible only if the two users are set
to contiguous call codes (marked with the same letter AA...CC..YY in the Microswitch programming table shown on page 33).
34
MT KIT 13
S1-8
Pushbutton 1
Pushbutton 2
OFF
Pushbutton 3
(0)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
OFF
Pushbutton 3
(0)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
OFF
Pushbutton 3
(0)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
OFF
Pushbutton 3
(0)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
ON
Pushbutton 3
(1)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
ON
Pushbutton 3
(1)
Pushbutton 4
Pushbutton 5
Pushbutton 1
Pushbutton 2
ON
Pushbutton 3
(1)
Pushbutton 4
Pushbutton 5
Button functions
Switchboard call
Self-ignition
Actuator control
Press-to-talk/Doctor
Single-residence intercom call
Single-residence intercom call
Self-ignition
Actuator control
Press-to-talk/Doctor
Switchboard call
Two-residence intercom call
(1)
Self-ignition
Actuator control
Press-to-talk/Doctor
Switchboard call
Switchboard call
Self-ignition
Actuator control
Press-to-talk/Doctor
Two-residence intercom call
(1)
Single-residence intercom call
Self-ignition
Two-residence intercom call
(1)
Press-to-talk/Doctor
Actuator control
Single-residence intercom call
Two-residence intercom call
(1)
Actuator control
Press-to-talk/Doctor
Self-ignition
Switchboard call
Self-ignition
Actuator control
Single-residence intercom call
Two-residence intercom call
(1)