TECHNICAL DATA / INSTALLATION
A1

1.0 PRE-INSTALLATION CHECKS

the leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the
movement and must move without frictions.
Before the installation of iDro, verify all dimensions etc. (see table c1)
Gate features must be uniformed with the standards and laws in force.
the gate can be automated only if it is in a good condition and its conditions comply with
the EN 12604 norm.
- the gate leaf does not have to have a pedestrian opening. in the opposite case it
is necessary to take the appropriate steps, in accordance with EN 12453 norm (for
instance; by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe
enough.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses (e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way
A: command button with manned operation (that is, operating as long as activated), like code AcG2013
B: Key selector with manned operation, like code AcG1010
c: Adjustable power of the motor
D: safety edges, like code AcG3010 and/or other safety devices to keep thrust force within the limits
of EN12453 regulation - Appendix A.
E: photocells, like code AcG8026 (to apply every 60÷70cm for all the height of the column of the
gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
CARACTERISTIQUES
Single-phase system voltage
Motor capacity with load
Power absorption
Max Thrust force
Rod retraction time (max. stroke)
Rod extension time
Max leaf length
Min leaf length
Max leaf weight
Operating temperature range
Max distance between centres for mounting
holes with fully extended rod
Max stroke - standard arm
Weight with oil
Oil quantity
Oil type
Protection degree
No. normative cycles
No. of daily operations suggested
Service
No. guaranteed consecutive cycles
1060
698
Measurements in mm
USE OF THE SHUTTER
skilled persons
skilled persons
(out of a public area*)
(public area)
A
B
c or E
c or E
c or E
c and D, or E
c and D, or E
c and D, or E
IDRO C 27/1B
230 V±10% 50/60Hz Hz
260W / 310W
1,14A / 1,44A
2000 N / 2500 N
17,5 sec
21,5 sec
1,8 m
1,2 m
250 kg
-20° / + 70°C
1002 mm ± 5
270 mm
8 kg
0,6 lt.
RIB Oil HC13
IP 55
30 - 17s/2s
200
60%
274


unrestricted use
not possible
c and D, or E
c and D, or E
c and D, or E
50
90