RIB IDRO C 27/1B Manuel D'instructions page 39

Masquer les pouces Voir aussi pour IDRO C 27/1B:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSERT THE TRANSMITTERS CODES
E - CODE ACQUISITION
CARRY OUT WITH GATE CLOSED !
N.B.: Should you make any mistake when using the button, repeat the operation but
only after having bridge the RESET spikes.
LED on
10 second interval to transmit
code settings by means of
remote control.
maximum 59 codes (tX433)
SINGLE RADIO CODE CONFIRMATION
LED on
2s
10 second time interval to
transmit code to be cancelled
by means of remote control
2s
CHECK OF CODES ENTERED
LED on
2s
2s
LED off
0,5s 0,5s
Four flashes indicate the end of the
time available to set codes.
code not acquired
code acquisition complete
the next pulse from the remote
control activates opening
LED off
Four flashes indicate end of time
allowed for cancellation of single
code
code not cancelled
the cancelled code will by indicated
by one flash when transmitted
LED off
other
codes
entered
CANCELLATION OF ALL RADIO CODES ENTERED
LED on
2s
2s
press s1 briefly
1 Blinking* = signal not valid
1 Flash**
= stored code or gate according to the procedure you chose.
2 Blinkings = code already present
2 Flashes = overlaid radio signals during the storage
3 Blinkings = saturated memory (max. 59 codes)
3 Flashes = Empty memory, no codes memorized.
4 Blinkings = End of available time for the storage or the cancellation of a single code.
4 Flashes = You want to cancel a code that was not stored in the memory
* Blinking: the LED is turned of for 0.50 seconds
**Flash: the LED is turned on for 0.25 seconds
ATTENTION! The receiver learns, along with the code, also the channel you want
to use. Therefore remember the button of the radio transmitter you
press during the code learning procedure, because that very button
will activate the system.
GENERAL TECHNICAL FEATURES
Humidity
power supply voltage
Frequency
transient main power drops
Max. power managed at the motor output
Max. load at the blinker output
Max. card power absorption (excluding the accessories) 50mA
current available for the photocells
protection degree
Weight of the equipment
Dimensions
TECHNICAL FEATURES OF THE RADIO
Frequency for the reception
Impedance
sensitivity
Energizing time
etc.
De-energizing time
current available on the radio connector
- All inputs shall be used as clean contacts without earthing, because the power supply is
generated in the card and is structured in such a way to guarantee the respect of double
and reinforced insulation to the elements under voltage
- All inputs are managed by a programmed circuit that carries out a self-control every time
the gate is operated.
K1 - power relay enabling the blinker
K2 - power relay enabling the opening M1
K3 - power relay enabling the closing M1
K4 - power relay enabling the clutch M1
K5 - power relay enabling the opening M2
K6 - power relay enabling the closing M2
K7 - power relay enabling the clutch M2
K8 - power relay to enable the electric lock


LED off
2s
No cancel confirmation
3 flashes = memory
empty confirmation
LED L1 (Red) SIGNALS
<95% without condensation
230V±10% (on request 120V/60Hz)
50/60Hz
20ms
1cV
40W with resistive load
0.4A±15% 12Vdc
ip54
0.80kg
14.7 x 6 x 18cm
433.92MHz
52Ω
>2,24µV
300ms
300ms
200mA 12Vdc
RELAY
G
B