should be measured with at least the same accuracy. If you are uncertain, contact
the Suunto technical service before changing the calibration.
To change the pressure sensor calibration:
1. In the Function menu, scroll to General and press Suunto. The General menu is
displayed.
2. Scroll to Sensor and press Suunto. The text S
current measured absolute air pressure is displayed as active.
3. With the arrow buttons, set the absolute air pressure value to match the measured
reference value and press Suunto. You return to the Function menu.
NOTE: You can return the original calibration by scrolling the sensor calibration
value until text DEFAULT is displayed in the middle row.
3.2.6. Units
This menu includes the units that are used with all the Suunto S6 functions and
settings. The settings include Time, Date, Temp, Pres, Elev, Asc/Dsc, Speed and
Slope, and they affect the way information is displayed in all the Suunto S6 modes.
Setting the time format
The time settings define whether the 12- or 24-hour display is used.
To change the time format:
1. In the Function menu, scroll to Units and press Suunto. The Units menu is dis-
played.
2. Scroll to Time and press Suunto. The time format field is activated.
3. Select the correct time format with the arrow buttons and press Suunto. The time
format is now set.
24
C
ENSOR
ALIBRATION
appears and the