3.2 Installation
Fig. 2: Installation instructions for the flue cascade systems BK 350 (Flue outlet at the top)
1
8
9
8
10
11
1
End cover with siphon connection
2
Clamp
3
Tee for flue entry
(for end cover with siphon connection)
4
Tee for flue exit
5
Tee for flue entry
(for end cover without siphon connection)
6
End cover without siphon connection
16
3
2
2
7
- Apply lubricant to gaskets
- Assemble components as shown in Fig. 2
Note: Route the flue with a fall towards the combustion equipment so the conden-
sate can drain from the flue to the central condensate collector or to the siphon
connection. The minimum fall for a horizontal flue is 3° (5.5 cm/m).