3.4 Identification
3.4.1 Type key
The S pumps described in this booklet are identified by the type designation stated in the confirmation of order and other documentation
supplied with the pump.
Note: The pump type described in this booklet is not available in all variants.
Example: S2.35.A100.1680.6.72S.H.488.G.N.D.61H.Z
Code
Explanation
S
Grundfos sewage and wastewater pump
ST
Multi-channel impeller pump installed in a column pipe
2
2-channel impeller
3
3-channel impeller
4
4-channel impeller
Maximum solids size
35
35/10=3.5 [in]
A100
Nominal diameter of pump outlet
[ ]
Nominal diameter of column pipe
Output power, P2
1680
P2/ 10 [hp]
4
4-pole motor
6
6-pole motor
8
8-pole motor
10
10-pole motor
12
12-pole motor
14
14-pole motor
72
Range 72
74
Range 74
78
Range 78
S
Super-high pressure
H
High pressure
M
Middle pressure
L
Low pressure
E
Extra-low pressure
F
Super-low pressure
S
Submersible installation without cooling jacket
C
Submersible installation with cooling jacket
D
Dry installation, vertical
H
Dry installation, horizontal
488
Impeller diameter
G
Impeller, pump- and stator housing: cast iron
Q
Impeller: stainless steel CF8M (DIN W.-Nr. 1.4408)
N
Non-explosion-proof version
Ex
Pump with explosion-proof motor
B
S pump with built-in SM 113 module.
D
S pump without built-in SM 113 module
05
50 Hz
06
60 Hz
6
Designation
Pump type
Impeller type
Pump passage [in]
Pump outlet, S type [in]
Column diameter, ST type [in]
Output power [hp]
Number of poles
Pump range
Pressure version
Installation
Impeller diameter [in]
Material code for impeller, pump- and stator housing
Pump version
2
Sensor version
Frequency [Hz]
1