1.3
TECHNICAL FEATURES
Model PLANET DEWY 30/50 BF
Maximum input
Minimum input
Maximum output
Minimum output
Water content
Electric Power consumption
Maximum C.H. pressure
Maximum C.H. temperature
Expansion vessel Water content
Expansion vessel Pre-charged
C.H. setting range
Hot water tank contents
Quantity and temper. of hot water
Maximum D.H.W. pressure
Weight
Orifice
Maximum manifold gas pressure
Minimum manifold gas pressure
Minimum gas supply pressure
Category IV
0-2000 ft/PD
Units
Natural gas Propane Natural gas Propane
kW
32.24
32.24
But/h
110,000
110,000
kW
8.8
8.8
But/h
30,000
30,000
kW
29.5
29.5
But/h
100,800
100,800
kW
8.0
8.0
But/h
27,300
27,300
l
6.0
6.0
USgal
1.32
1.32
W
160
160
bar
3, 1
3, 1
psi
45.0
45.0
°C
85
85
°F
185
185
l
10
10
USgal
2.2
2.2
bar
1
1
psi
14.5
14.5
°C
10-80
10-80
°F
50-176
50-176
l
42
42
USgal
9.3
9.3
°C/l
622.5
622.5
°C/USgal
136.9
136.9
bar
8.6
8.6
psi
125
125
kg
70
70
lb
154
154
ø mm
6.9
4.6
inches
0,271
0, 1 81
mbar
6.5
7.5
"W.C.
2.61
3.01
mbar
0.65
0.70
"W.C.
0,261
0,281
mbar
8.7
19.9
"W.C.
3.5
7.99
FOR EITHER DIRECT VENT INSTALLATION OR FOR
INSTALLATION USING INDOOR COMBUSTION AIR
2000-4500 ft/PD
29.31
29.31
100,000
100,000
8.8
8.8
30,000
30,000
26.8
26.8
91,600
91,600
8.0
8.0
27,300
27,300
6.0
6.0
13.2
1.32
160
160
3, 1
3, 1
45.0
45.0
85
85
185
185
10
10
2.2
2.2
1
1
14.5
14.5
10-80
10-80
50-176
50-176
42
42
9.3
9.3
622.5
622.5
136.9
136.9
8.6
8.6
125
125
70
70
154
154
6.9
4.6
0,271
0, 1 81
6.5
7.5
2.61
3.01
0.65
0.70
0,261
0,281
8.7
19.9
3.5
7.99
CLEARANCES FROM
COMBUSTIBLE MATERIALS:
Bottom: 0 mm (0 in.)
Sides: 10 mm (0.4 in.)
Vent: 10 mm (0.4 in.)
Front: 0 mm (0 in.)
Top: 0 mm (0 in.)
Hot Water Pipes: 10 mm (0.4 in.)
CLEARANCES FROM SERVICE
AND PROPER OPERATION:
Bottom: 150 mm (6 in.)
Sides: 150 mm (6 in.)
Front: 600 mm (24 in.)
Top: 150 mm (6 in.)
MINIMUM CLEARANCES
FROM ELECTRIC METERS,
GAS METERS, REGULATORS
AND RELIEF EQUIPMENT :
US:
4 feet (1.22 m)
CND:
6 feet (1.8 m)
ENG
FR
5