1.3
TECHNICAL FEATURES
ENG
FR
Model PLANET DEWY 30 BFT
Maximum input
Minimum input
Maximum output
Minimum output
Water content
Electric Power consumption
Maximum C.H. pressure
Maximum C.H. temperature
Expansion vessel Water content
Expansion vessel Pre-charged
C.H. setting range
Weight
Orifice
Maximum manifold gas pressure mbar
Minimum manifold gas pressure mbar
Minimum gas supply pressure
Category IV
4
0-2000 ft/PD
Units
Natural gas Propane Natural gas
kW
32.24
32.24
But/h
110,000
110,000 100,000
kW
8.8
8.8
But/h
30,000
30,000
kW
29.5
29.5
But/h
100,800
100,800
kW
8.0
8.0
But/h
27,300
27,300
l
6.0
6.0
USgal
1.32
1.32
W
175
175
bar
3. 1
3. 1
psi
45.0
45.0
°C
85
85
F
185
185
l
8
8
USgal
2. 1
2. 1
bar
1
1
psi
14.5
14.5
°C
10-80
10-80
F
50-185
50-185
kg
49
49
lb
108
108
ø mm
6.9
4.6
inches
0,271
0, 1 81
6.5
7.5
"W.C.
2.61
3.01
0.65
0.70
"W.C.
0,261
0,281
mbar
8.7
19.9
"W.C.
3.5
7.99
FOR EITHER DIRECT VENT INSTALLATION
OR FOR INSTALLATION USING INDOOR
COMBUSTION AIR
2000-4500 ft/PD
Propane
29.31
29.31
100,000
8.8
8.8
30,000
30,000
26.8
26.8
91,600
91,600
8.0
8.0
27,300
27,300
6.0
6.0
1.32
1.32
175
175
3. 1
3. 1
45.0
45.0
85
85
185
185
8
8
2. 1
2. 1
1
1
14.5
14.5
10-80
10-80
50-185
50-185
49
49
108
108
6.9
4.6
0,271
0, 1 81
6.5
7.5
2.61
3.01
0.65
0.70
0,261
0,281
8.7
19.9
3.5
7.99
CLEARANCES FROM
COMBUSTIBLE MATERIALS:
Bottom: 0 mm (0 in.)
Sides: 10 mm (0.4 in.)
Vent: 10 mm (0.4 in.)
Front: 0 mm (0 in.)
Top: 0 mm (0 in.)
Hot Water Pipes: 10 mm (0.4 in.)
CLEARANCES FROM SERVICE
AND PROPER OPERATION:
Bottom: 150 mm (6 in.)
Sides: 150 mm (6 in.)
Front: 600 mm (24 in.)
Top: 150 mm (6 in.)
MINIMUM CLEARANCES
FROM ELECTRIC METERS,
GAS METERS, REGULATORS
AND RELIEF EQUIPMENT :
US:
4 feet (1.22 m)
CND:
6 feet (1.8 m)