120V Hard Wiring Installation - Napoleon NEFB33H Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12
3.3.5

120V HARD WIRING INSTALLATION

EN
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
120V HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire
the appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V
minimum 15 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
NOTE: There are 4 wires from the fi replace junction; white (neutral), black (power L1), Red (Power L2)
and green (ground) that connect to 120V power supply (breaker panel).
W415-2165 / E / 02.23.17
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
Voltage Selector Switch
RED
WHITE (N)
WHITE
BLACK (L1)
GREEN (G)
BLACK
GREEN
WARNING
!
Wire Nut
RED
WHITE
BLACK
GREEN
White, Green and
Black wires:
Connect to 120V
power supply.
WHITE (N)
BLACK (L1)
GREEN (G)

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Nefb40h