120V Hard Wiring Installation; Nefl42 / 50 / 60 / 74 Chs 120V Hardwiring - Napoleon Alluravision Serie Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

installation
EN
4.5

120V hard wiring installation

4.5.1 NEFL42 / 50 / 60 / 74 CHS 120V hardwiring

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
If it is necessary to hard wire this appliance, a qualifi ed electrician
must remove the cord connection and wire the appliance directly to
the household wiring. The wire and power supply breaker must be
rated for 120V minimum 15 amps.
This appliance must be electrically connected and grounded in
accordance with local codes if hard wired. In the absence of local
codes, use the current CSA C22.1 Canadian Electrical Code in
Canada or the current ANSI/NFPA 70 National
Electrical Code in the United States.
Before hardwiring the appliance, remove the junction box control cover by removing the fasteners as shown.
1. Remove the securing screws from the electrical cover plate, located on the rear left side of the appliance.
2. Loosen the securing screws from the terminal block to remove the cord from the terminal block.
3. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole from the terminal
block.
4. Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by tightening
the screws on the (N) slots.
5. Repeat step 4 with Black (L1) and Green (G), securing them to their designated slots in the terminal block.
6. Re-install cover plate.
16
W415-2212 / F / 04.23.19
BLACK (L1)
WHITE (N)
BLACK (L1)
GREEN (G)
(N)
WHITE (N)
(L1)
(G)
GREEN (G)
WHITE (N)
BLACK (L1)
GREEN (G)
120V