Voltage Selector Switch Location; 120 Volt Cord Plug Installation - Napoleon NEFB33H Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3.3 VOLTAGE SELECTOR SWITCH LOCATION

WARNING: The voltage selector switch must match the incoming power supply voltage. The heater
will overheat if the switch does not match the incoming power supply voltage.
CAUTION: When changing the voltage selector switch from 240 volts to 120 volts (or vice versa) the
power supply must be turned off fi rst.
The voltage selector switch is located inside the appliance (Fig. 1).
Fig.1
A.
Remove the door, refer to "DOOR REMOVAL" section.
B.
Remove metal cover from the voltage selector switch.
C.
Change the voltage selector switch position. NOTE : Factory default setting is 120 volt (115
printed on the switch) if you use 120 volt power supply you do not need to make the changes.
When wiring the appliance for 240 volt the voltage selector switch should be in 230 volt position on
the switch.

3.3.4 120 VOLT CORD PLUG INSTALLATION

The factory default setting is 120 volt cord plug installation confi guration. Simply plug the appliance to a
grounded 120V 15 Amp outlet box.
NOTE: Must be connected to a dedicated 15 Amp circuit. The use of an extension cord is NOT
permitted.
Voltage Selector Switch
11
EN
W415-2165 / E / 02.23.17

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Nefb40h

Table des Matières