120V Hard Wiring Installation - Napoleon Ascent Electric Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

installation
EN
3.3.5

120V hard wiring installation

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualified service person should service
and repair this electric appliance.
120V HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V minimum
15 Amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
note:
There are 4 wires from the appliance junction: white (neutral), black (power L1), Red (Power L2) and green
(ground) that connect to 120V power supply (breaker panel).
14
W415-2165 / G / 08.15.18
Voltage Selector Switch
RED
WHITE (N)
WHITE
BLACK (L1)
BLACK
GREEN (G)
GREEN
White, Green and
Connect to 120V
Wire Nut
RED
WHITE
BLACK
GREEN
Black wires:
power supply.
WHITE (N)
BLACK (L1)
GREEN (G)